1.Features:
① Being able to be directly soldered on PCB, perfect outline.
② High frequency.
③ Completely sealed, strong mechanical and environmental endurance, strong dielectric strength, safe and reliable.
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 2kHz~200kHz
4.Insulation Thermal Class: Class B (130℃)
5.Safety Features:
① Insulation resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 6KV 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0.
6.Outline Drawing, Installation Dimension and Coil Diagram:( tolerance±0.3 mm)
  

7.Typical Application and Technical Parameters:
Model  | Rated Input Current  | Rated Output Current  | Rated Sampling Resistance  | Rated Sampling Voltage  | Non Linearity  | Withstand Voltage  | 
TA1526-1  | 50A  | 250mA  | 30Ω  | 7.5V  | ≤2%  | ≥6KV  | 
TA1526-2  | 50A  | 100mA  | 150Ω  | 15V  | ≤2%  | ≥6KV  | 
TA1526-3  | 50A  | 50mA  | 600Ω  | 30V  | ≤2%  | ≥6KV  | 
8.Attention:
① Connect the primary winding of the current transformer in series with the measured current loop. Operate the secondary winding in a near short-circuit mode.
② Do not allow the secondary winding of the current transformer to be open-circuited. Do not install any fuse on the secondary winding.