LI056V5/2016
1.Features:
① Vertical core-through, printed circuit board directly soldered and installed;
② Small size, high frequency, beautiful appearance;
③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability .
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 2kHz~200kHz
4.Insulation Thermal Class: Class B (130℃)
5.Safety Features:
① Insulation resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 6KV 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0. 
6.Outline Drawing, Installation Dimension and Coil Diagram:( tolerance±0.3 mm)
① Outline drawing and installation dimensions are shown in Figure 1:
② The coil diagram is shown in Figure 2.

 
7.Typical Application and Technical Parameters:( tolerance±0.3mm )
See the table below for performance parameters when applied as shown in Figure 3
Model  | Rated Input Current  | Rated Output Current  | Rated Sampling Resistance  | Rated Sampling Voltage  | Non-linearity  | 
TA0813-1  | 20A  | 100mA  | 25Ω  | 2.5V  | ≤2%  | 
TA0813-2  | 20A  | 40mA  | 125Ω  | 5V  | ≤2%  | 
TA0813-3  | 20A  | 20mA  | 500Ω  | 10V  | ≤2%  | 
8.Attention:
① Connect the primary winding of the current transformer in series with the measured current loop. Operate the secondary winding in a near short-circuit mode.
② Do not allow the secondary winding of the current transformer to be open-circuited. Do not install any fuse on the secondary winding.