Home
Products
Power Transformers
Voltage/Current Transformers
Power Sensors
Power Modules
Anti-resonance Reactors
Applications
Electric Power Automation and Intelligence
Power Equipment
Rail Transit
Industrial Automation
Download
About Us
Contact Us
Login
Register
CN
TA5266 Series Box-type AC Current Transformers
77.gif
TA5266 Series Box-type AC Current Transformers
Features:
① Flexible in installation modes: can be fixed on primary wire or bottom board.
② Suitable for various primary wires, such as flat-type wires, round wires, or cables.
③ Output terminals are standard type with screws, which is convenient for connecting wires on the spot.
④ Box structure, encapsulated by a plastic shell, with a sleek design.
TA5266系列 General Technical Specifications for Standard Products:

1Features: 

 Flexible in installation modes: can be fixed on primary wire or bottom board.

Suitable for various primary wires, such as flat-type wires, round wires, or cables.

Output terminals are standard type with screws, which is convenient for connecting wires on the spot.

Box structure, encapsulated by a plastic shell, with a sleek design.

 

2Ambient conditions:

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg);

 

3Range of Operating Frequency: 20Hz~1kHz;

 

4Insulation Rating: ClassB (130).

 

5Safety features:

 Insulation resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 4000V 50Hz/1min;

 Fire retardancy: In conformity with UL94-Vo.

 



6Outline Drawing, Installation Dimension and Coil Diagram

image.png

 Remark: Two support legs to be fixed on bottom board, one support leg with screws are included in package along with every product.


                                                  

² Installation instruction:

 Mounted on bottom board:

Take two support legs (included in package

along with the product) and insert them

into the sockets as shown in Fig. below.

The center distance between the mounting holes is

57×42.5; The diameter of the mounting hole for

the support leg is Φ 5.0, and then use M5 screw 

to fix the current transformer on the bottom board.

 

 Mounted on primary wire:

Take one support leg with M5 hole (included in

package along with the product) and insert it into

the socket as shown in Fig. below. The center

distance between the M5 hole is 57; fix the current







transformer on the primary wire with M5 screw.

image.png

7Typical Usage and Parameters:

The parameters in this application as shown in the upper right Fig. are listed in table below: 

 Model

 Rated Input Current

 Rated Output Current

 Rated Sample Resistor

RL

 Rated Sample Voltage

Phase Shift

 Non Linearity

 Linear Range

Withstand Voltage

TA5266-1

300A

0.15A

40Ω

6V

≤30’

≤0.5%

3 times of rated value

≥4KV

TA5266-2

750A

0.15A

80Ω

12V

≤30’

 

Remarks:

a. In practical applications, it is recommended to use a sampling resistor that is smaller than or equal to the rated value given in the table above, as this can help to improve the non-linearity and phase shift of the device.

b. If the required current ratio is not listed in the table above, we can provide custom-made options to meet specific needs.

8Attention:

 Connect the primary of the current transformer in series with the measured current loop, and operate the secondary in near short circuit mode.

 Do not allow the secondary of the current transformer to be open circuit and do not install any fuse.
















Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search