TA2030 Series Precision AC Current Transformers
37.gif
TA2030 Series Precision AC Current Transformers
① The output coil comes with standard plug-in leads for easy use and an elegant appearance.
② It is completely sealed, with strong mechanical and environmental endurance, high dielectric strength, ensuring safety and reliability.
TA2030 General Technical Specifications for Standard Products:

1Features:

 The output coil comes with standard plug-in leads for easy use and an elegant appearance.

 It is completely sealed, with strong mechanical and environmental endurance, high dielectric strength, ensuring safety and reliability.

 

2Ambient Conditions:

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg);

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass F (155℃)

 

5Safety Features:

 Insulation resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 6000V 50Hz/1min;

 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram:( tolerance ± 0.5mm )

image.png

7Typical Application and Parameters:


The parameters in this application as shown in the figure are listed in Table below:

image.png

Table:

 

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

RL

Rated Sampling Voltage

Phase Shift

Non Linearity

Linear Range

Withstand Voltage

TA2030-00

120A

40mA

150Ω

6V

≤6’

≤0.2%

≥1.5 times of rated value

≥6KV

TA2030-00M

120A

40mA

187.5Ω

7.5V

≤7.5’

≤0.25%

TA2030-01

100A

50mA

80Ω

4V

≤8’

≤0.2%

TA2030-01M

100A

50mA

100Ω

5V

≤10’

≤0.25%

TA2030-02

90A

60mA

50Ω

3V

≤10’

≤0.2%

TA2030-02M

90A

60mA

62.5Ω

3.75V

≤12.5’

≤0.25%

TA2030-03

60A

60mA

30Ω

1.8V

≤10’

≤0.2%

TA2030-03M

60A

60mA

37.5Ω

2.25V

≤12.5’

≤0.25%

 

Notes:

aIn practical applications, the sampling resistor should be smaller than or equal to the rated value given in table above in order to improve the non-linearity and phase shift.

bWe can have it customer-made if required current ratio is not listed in the table above.

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.



Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search