1.Features:
① External core -through busbar , the number of turns of the busbar can be selected by the user, and the printed circuit board is directly soldered and installed;
② Small size , large via hole, high precision, beautiful appearance ;
③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, safe and reliable.
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 20Hz~1kHz
4.Insulation Thermal Class:Class B (130°C)
5.Safety Features:
① Insulation resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 6000V 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0.
6. Outline Drawing, Installation Dimension and Coil Drawing : ( tolerance ± 0.5mm )
① Outline drawing and installation dimensions are shown in Figure 1:
② The coil diagram is shown in Figure 2:
7. Typical Application and Performance Parameters:
① When the sampling voltage is directly obtained by the resistance method ( see Figure 3 ) , the performance parameters are shown in
Table 1:
Model | Rated Input Current | Rated Output Current | Rated Sampling Resistance R L | Rated Sampling Voltage | Phase Shift | Non-linearity | Linear Range |
TA1418-1M | 2A | 10 mA | 100Ω | 1V | ≤30' | ≤0.25% | ≥ 1.5 times of the rated value |
TA1418-2M | 2A | 5 mA | 400Ω | 2V | ≤ 30' | ≤0.25% |
② When the sampling voltage is obtained by the IC method ( see Figure 4 ) , the performance parameters are shown in Table 2 .
Table 2:
Model | Rated Input Current | Rated Output Current | Rated Sampling Voltage | Phase Shift | Non-linearity | Linear Range |
TA1418-1M | 2A | 10 mA | ≤1/2 times IC power supply voltage | ≤5' | ≤0.1% | ≥ 1.5 times of the rated value |
TA1418-2M | 2A | 5 mA |
8.Attention:
① Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.
② Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.