TA1338 Series Vertical Core Type Miniature Precision AC Current Transformer
28.png
TA1338 Series Vertical Core Type Miniature Precision AC Current Transformer
Features:
① Vertical core-through, printed circuit board directly welded and installed, beautiful appearance;
② Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, high precision, safe and reliable.
TA1338 General Technical Specifications for Standard Products:

1Features:

① Vertical core-through, printed circuit board directly welded and installed, beautiful appearance;

② Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, high precision, safe and reliable.

 

2Ambient conditions:                    

① Ambient temperature: -55℃+85℃;

② Relative humidity: ≤90% at 40℃;

③ Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass B (130°C)

 

5Safety Features:

① Insulation resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 6000V 50Hz/1min;

③ Fire retardancy: In conformity with UL94-V0.

 

6. Outline Drawing, Installation Dimension and Coil Diagram: ( tolerance ± 0.5mm )

① Outline drawing and installation dimensions are shown in Figure 1:

image.png

② The coil diagram is shown in Figure 2:

image.png

7. Typical Application and Performance Parameters:

When the sampling voltage is directly obtained by the resistance method ( Figure 3 );

Table 1

Model

Rated

Input Current

Rated

Output Current

Rated

Sampling Resistance

R L

Rated

Sampling Voltage

Non-linearity

Linear Range

TA1338-01M

50A

50 mA

40Ω

2V

≤0.2%

≥ 1.5 times of

the rated value

TA1338-02M

50A

25 mA

160Ω

4V

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.


Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search