1.Features:
① Small size, high precision; printed circuit board directly soldered and installed, easy to use, beautiful appearance;
② Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, safe and reliable.
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 20Hz~20kHz
4.Insulation Thermal Class: Class F grade (155°C)
5.Safety Features:
① Dielectric resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 2KV 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0.
6. Outline Drawing, Installation Dimension and Coil Diagram (Figure 1) : (tolerance ± 0.5mm)
 
7. Typical Application and Performance Parameters:
TV1012 is a current-mode voltage transformer, the typical application is as shown in Figure 2 and Figure 3, and the performance parameters are shown in the table below.

Usage  | Model  | Input Voltage  | Output Voltage  | Phase Shift  | Non-linearity  | Linear Range  | Rated Current  | Withstand Voltage(kV)  | 
Used as in Fig. 2  | TV1012-1  | ≤1000Vac  | ≤0.5Vac  | ≤30'  | ≤0.2%  | 1.5 times of the rated value  | 2mA/2mA  | ≥2  | 
TV1012-1M  | ≤0.625Vac  | ≤40'  | ≤0.25%  | |||||
Used as in Fig. 3  | TV1012-1  | ≤1000Vac  | ≤1/2 IC’s power supply  | ≤5'  | ≤0.1%  | 2 times of the rated value  | ||
TV1012-1M  | ≤5'  | ≤0.1%  | 
8. Attention:
This voltage transformer model is a current-type transformer. Therefore, an open circuit is not permitted in the secondary circuit, and no fuse should be connected in the secondary circuit.