TA1321 Series Minitype Precision AC Current Transformers
TA1321系列卧式穿芯小型精密交-1.gif
TA1321 Series Minitype Precision AC Current Transformers
Features:
① Being able to be directly welded on PCB, beautiful outline.
② It is completely encapsulated, ensuring strong mechanical and environmental endurance, high voltage insulating ability, high accuracy, and safety and reliability.
TA1321 General Technical Specifications for Standard Products:

1Features: 

 Being able to be directly welded on PCB, beautiful outline. 

 It is completely encapsulated, ensuring strong mechanical and environmental endurance, high voltage insulating ability, high accuracy, and safety and reliability.

 

2Ambient Conditions:

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass F (155℃)

 

5Safety Features:

 Dielectric resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 6000V 50Hz/1min

 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram:( tolerance ± 0.5mm )

image.png

7Typical Application and Technical Parameters:

The parameters are listed in Table 1 while the sampling voltage is obtained directly by using a resistor (as shown in Fig.1 below).

The parameters are listed in Table 2 while the sampling voltage is obtained by using an IC (as shown in Fig.2 below). 

image.png

   

Table 1

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

RL

Rated Sampling Voltage

Phase Shift

Non Linearity

Linear Range

Withstand Voltage

TA1321-1K

10A

25mA

32Ω

0.8V

≤30’

≤0.2%

2 times of the rated value

≥6KV

TA1321-1KM

10A

25mA

4

1.0V

≤37

≤0.25%

TA1321-2K

10A

10mA

200Ω

2.0V

≤20’

≤0.2%

TA1321-2KM

10A

10mA

25

2.5V

25

≤0.25%

TA1321-3K

20A

10mA

300Ω

3.0V

≤15’

≤0.2%

TA1321-3KM

20A

10mA

375Ω

3.75V

19

≤0.25%

TA1321-4K

30A

6mA

500Ω

3.0V

≤12’

≤0.2%

≥1.5 times of the rated value

TA1321-4KM

30A

6mA

625Ω

3.75V

15

≤0.25%

TA1321-5K

40A

50mA

20Ω

1.0V

≤15’

≤0.2%

TA1321-5KM

40A

50mA

25Ω

1.0V

≤19

≤0.25%

TA1321-6K

20A

25mA

20Ω

0.5V

≤20’

≤0.2%

TA1321-6KM

20A

25mA

25Ω

0.625V

≤25

≤0.25%

 

Table 2

Model

Rated Input Current

Rated Output Current

Rated Sampling Voltage

Phase Shift

Non Linearity

Linear Range

Withstand Voltage

TA1321-1K

10A

25mA

 

≤1/2 IC’s power supply

≤5’

≤0.1%

 

2 times of the rated value

≥6KV

TA1321-1KM

10A

25mA

TA1321-2K

10A

10mA

TA1321-2KM

10A

10mA

TA1321-3K

20A

10mA

TA1321-3KM

20A

10mA

TA1321-4K

30A

6mA

TA1321-4KM

30A

6mA

TA1321-5K

40A

50mA

TA1321-5KM

40A

50mA

TA1321-6K

20A

25mA

TA1321-6KM

20A

25mA

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.


Application Case