1.Features:
① Being able to be directly welded on PCB, beautiful outline.
② It is completely encapsulated, ensuring strong mechanical and environmental endurance, high voltage insulating ability, high accuracy, and safety and reliability.
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 20Hz~1kHz
4.Insulation Thermal Class:Class F (155℃)
5.Safety Features:
① Dielectric resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 6000V 50Hz/1min
③ Fire retardancy: In conformity with UL94-V0.
6.Outline Drawing, Installation Dimension and Coil Diagram:( tolerance ± 0.5mm )
7.Typical Application and Technical Parameters:
①The parameters are listed in Table 1 while the sampling voltage is obtained directly by using a resistor (as shown in Fig.1 below).
②The parameters are listed in Table 2 while the sampling voltage is obtained by using an IC (as shown in Fig.2 below).
Table 1:
Model | Rated Input Current | Rated Output Current | Rated Sampling Resistance RL | Rated Sampling Voltage | Phase Shift | Non Linearity | Linear Range | Withstand Voltage |
TA1321-1K | 10A | 25mA | 32Ω | 0.8V | ≤30’ | ≤0.2% | ≥2 times of the rated value | ≥6KV |
TA1321-1KM | 10A | 25mA | 40Ω | 1.0V | ≤37’ | ≤0.25% | ||
TA1321-2K | 10A | 10mA | 200Ω | 2.0V | ≤20’ | ≤0.2% | ||
TA1321-2KM | 10A | 10mA | 250Ω | 2.5V | ≤25’ | ≤0.25% | ||
TA1321-3K | 20A | 10mA | 300Ω | 3.0V | ≤15’ | ≤0.2% | ||
TA1321-3KM | 20A | 10mA | 375Ω | 3.75V | ≤19’ | ≤0.25% | ||
TA1321-4K | 30A | 6mA | 500Ω | 3.0V | ≤12’ | ≤0.2% | ≥1.5 times of the rated value | |
TA1321-4KM | 30A | 6mA | 625Ω | 3.75V | ≤15’ | ≤0.25% | ||
TA1321-5K | 40A | 50mA | 20Ω | 1.0V | ≤15’ | ≤0.2% | ||
TA1321-5KM | 40A | 50mA | 25Ω | 1.0V | ≤19’ | ≤0.25% | ||
TA1321-6K | 20A | 25mA | 20Ω | 0.5V | ≤20’ | ≤0.2% | ||
TA1321-6KM | 20A | 25mA | 25Ω | 0.625V | ≤25’ | ≤0.25% |
Table 2:
Model | Rated Input Current | Rated Output Current | Rated Sampling Voltage | Phase Shift | Non Linearity | Linear Range | Withstand Voltage |
TA1321-1K | 10A | 25mA |
≤1/2 IC’s power supply | ≤5’ | ≤0.1% |
≥2 times of the rated value | ≥6KV |
TA1321-1KM | 10A | 25mA | |||||
TA1321-2K | 10A | 10mA | |||||
TA1321-2KM | 10A | 10mA | |||||
TA1321-3K | 20A | 10mA | |||||
TA1321-3KM | 20A | 10mA | |||||
TA1321-4K | 30A | 6mA | |||||
TA1321-4KM | 30A | 6mA | |||||
TA1321-5K | 40A | 50mA | |||||
TA1321-5KM | 40A | 50mA | |||||
TA1321-6K | 20A | 25mA | |||||
TA1321-6KM | 20A | 25mA |
8.Attention:
① Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.
② Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.