TA1320A Series Minitype AC Current Transformers
TA1320A系列立式穿芯小型交流电流互感器-1.gif
TA1320A Series Minitype AC Current Transformers
1.Features:
① Being able to be directly welded on PCB, beautiful outline;
② Completely encapsulated, it has strong mechanical and environmental endurance, high voltage insulating ability, high accuracy, and is safe and reliable.
TA1320A General Technical Specifications for Standard Products:

1Features: 

① Being able to be directly welded on PCB, beautiful outline;

② Completely encapsulated, it has strong mechanical and environmental endurance, high voltage insulating ability, high accuracy, and is safe and reliable.

 

2Ambient Conditions:

① Ambient temperature: -55℃+85℃;

② Relative humidity: ≤90% at 40℃;

③ Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass F (155℃)


 

5Safety Features:

① Insulation resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 6000V 50Hz/1min; 

③ Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram: ( tolerance ± 0.5mm )

image.png

image.png


7Typical Application and Parameters

The parameters are listed in the following table while the application is shown as the figure.

image.png

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

RL

Rated Sampling Voltage

Rated Sampling Voltage

Non Linearity

Linear Range

Withstand Voltage

TA1320A-1M

50A

100mA

12.5Ω

1.25V

≤30’

≤0.2%

2 times of the rated value

≥6KV

TA1320A-2M

50A

50mA

50Ω

2.5V

≤20’

≤0.2%

TA1320A-3M

50A

25mA

200Ω

5.0V

≤15’

≤0.2%

Notes:

aIn practical applications, the sampling resistor should be smaller than or equal to the rated value given in table above in order to improve the non-linearity and phase shift.

bWe can have it customer-made if required current changing ratio is not listed in the table above.

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.

Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search