TA1319 Series Vertical Core Type Miniature AC Current Transformer
TA1319系列立式穿芯微型交流电流互感器-1.jpg
TA1319 Series Vertical Core Type Miniature AC Current Transformer
Features:
① Vertical core-through, printed circuit board directly soldered and installed ;
② Small size, high precision , beautiful appearance;
③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability.
TA1319 General Technical Specifications for Standard Products:

1Features:

① Vertical core-through, printed circuit board directly soldered and installed ;

② Small size, high precision , beautiful appearance;

③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability.

 

2Ambient conditions:                    

① Ambient temperature: -55℃+85℃;

② Relative humidity: ≤90% at 40℃;

③ Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass B (130°C)

 

5Safety Features:

① Insulation resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 6000V 50Hz/1min;

③ Fire retardancy: In conformity with UL94-V0.

 

6. Outline Drawing, Installation Dimension and Coil diagram : ( tolerance ± 0.5mm )

image.png

7. Typical Application and Performance Parameters:

① When the sampling voltage is directly obtained by the resistance method ( as shown in Figure 3 ) , the performance parameters are shown in Table 1;

② When using the IC method to obtain the sampling voltage ( as shown in Figure 4 ) , the performance parameters are shown in Table 2.

image.png


Table 1 :

Model

Rated

Input Current

Rated

Output Current

Rated

Sampling Resistance

Rated

Sampling Voltage

Phase Shift

Non-linearity

Linear Range

TA1319-01

5A

5 mA

140Ω

0.7V

≤ 30'

≤0. 2 %

≥ 2 times of

the rated value

TA1319-01M

5A

5 mA

200Ω

1.0V

≤ 30'

≤0. 25 %

TA1319-02

5A

2.5 mA

560Ω

1.4V

≤ 25'

≤0. 2 %

TA1319-02M

5A

2.5 mA

800Ω

2.0V

≤ 25'

≤0. 25 %

 

Table 2:

Model

Rated

Input Current

Rated

Output Current

Rated Sampling Voltage

Phase Shift

Non-linearity

Linear Range

TA1319-1

5A

5 mA

≤1/2 times IC power supply voltage

≤5'

≤0.1%

≥ 2 times of

the rated value

TA1319-1M

5A

5 mA

TA1319-2

5A

2.5 mA

TA1319-2M

5A

2.5 mA

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.

Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search