TA1218 Series Vertical Core Type Miniature AC Current Transformer
TA1218系列立式穿芯微型交流电流互感器-1.jpg
TA1218 Series Vertical Core Type Miniature AC Current Transformer
Features:
① Vertical core-through, printed circuit board directly soldered and installed;
② Small size, high precision, beautiful appearance;
③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability.
TA1218 General Technical Specifications for Standard Products:

1Features:

① Vertical core-through, printed circuit board directly soldered and installed;

② Small size, high precision, beautiful appearance;


③ Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability. 

2Ambient Conditions:

① Ambient temperature: -55℃+85℃;

② Relative humidity: ≤90% at 40℃;

③ Atmospheric pressure: 8601060mbar(about 650800mmHg).

3Operating Frequency Range: 20Hz~1kHz

4Insulation Thermal ClassClass B (130°C)

5Safety Features:

① Insulation resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 6kV 50Hz/1 min;

③ Fire retardancy: In conformity with UL94-V0.

6. Outline Drawing, Installation Dimension and Coil Diagram : ( tolerance ± 0.5mm )

① Outline drawing and installation dimensions are shown in Figure 1:

image.png  

image.png② The coil diagram is shown in Figure 2:

 

 

 

 

  7. Typical Application and Performance Parameters:

image.png

① When the sampling voltage is directly obtained by the resistance method (as shown in Figure 3), the performance parameters are as shown in Table 1.

② When using the IC method to obtain the sampling voltage (as shown in Figure 4), the performance parameters are as shown in Table 2.

Table 1 :

Model

Rated

Input Current

Rated

Output Current

Rated

Sampling Resistance

Rated

Sampling Voltage

Phase Shift

Non-linearity

Linear Range

TA1218-1M

10A

10mA

150Ω

1.5V

≤25'

≤0.2%

≥2 times of the rated value

TA1218-2M

20A

10mA

300Ω

3.0V

≤20'

Table 2 :

Model

Rated

Input Current

Rated

Output Current

Rated Sampling Voltage

Phase Shift

Non-linearity

Linear Range

TA1218-1M

10A

10mA

≤1/2 times IC power supply voltage

≤5'

≤0.1%

≥2 times of the rated value

TA1218-2M

20A

10mA

 8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.