TA1016 Series Microminiature Precision AC Current Transformers
TA1016系列立式穿芯微型精密-1.gif
TA1016 Series Microminiature Precision AC Current Transformers
Features:
① The busbar is built-in and directly soldered to the printed circuit board for installation;
② Compact in size, high precision, and aesthetic appearance;
③ Fully enclosed, with good mechanical and environmental performance, and strong voltage isolation capability.
TA1016 General Technical Specifications for Standard Products:

1Features: 

 The busbar is built-in and directly soldered to the printed circuit board for installation;

 Compact in size, high precision, and aesthetic appearance;

 Fully enclosed, with good mechanical and environmental performance, and strong voltage isolation capability.

 

2Ambient Conditions:

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg);

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass F (155℃).

 

5Safety features:

 Insulation resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 6000V 50Hz/1min;

 Fire retardancy: In conformity with UL94-V0.

 

 

6Outline Drawing, Installation Dimension and Coil Diagram:

image.png

 

7Typical Application and Technical Parameters:

The parameters are listed in Table 1 while the sampling voltage is obtained directly by using a resistor (as shown in Fig.1 below).

 The parameters are listed in Table 2 while the sampling voltage is obtained by using an IC (as shown in Fig.2 below). 

image.png

Table 1

Model

Rated Input Current

Rated Output Current

Rated Sample Resistor

RL

Rated Sample Voltage

Phase Shift

Non Linearity

Linear Range

Withstand Voltage

TA1016-1

10A

10mA

50Ω

0.5V

≤20’

≤0.2%

≥1.5 times of rated value

≥6KV

TA1016-1M

10A

10mA

62.5Ω

0.625V

≤25’

≤0.25%

TA1016-2

5A

2.5mA

400Ω

1V

≤20’

≤0.2%

≥2 times of rated value

TA1016-2M

5A

2.5mA

500Ω

1.25V

≤25’

≤0.25%

Table 2

Model

Rated Input Current

Rated Output Current

Rated Sample Voltage

Phase Shift

Non Linearity

Linear Range

Withstand Voltage

TA1016-1

10A

10mA

≤1/2 IC’s power supply

≤5’

≤0.1%

≥2 times of rated value

≥6KV

TA1016-1M

10A

10mA

TA1016-2

5A

2.5mA

TA1016-2M

5A

2.5mA

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.