1. Features:
① Vertical core-through, printed circuit board directly soldered and installed;
② Small size, high precision, beautiful appearance;
② Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability.
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 20Hz~1kHz
4.Insulation Thermal Class: Class B (130°C)
5.Safety Features:
① Dielectric resistance: >1000MΩ in normal condition;
② Insulation withstand voltages:6KV 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0.
6. Outline Drawing, Installation Dimension and Coil Diagram : ( tolerance ± 0.5mm)
7.Typical Application and Technical Parameters:
① See Table 1 for the performance parameters when the sampling voltage is directly obtained by the resistance method ( as shown in Figure 3 ) ;
② See Table 2 for the performance parameters when the sampling voltage is obtained by the IC method ( as shown in Figure 4 ) .
Table 1:
Model | Rated Input Current | Rated Output Current | Rated Sampling Resistance | Rated Sampling Voltage | Phase Shift | Non Linearity | Linear Range |
TA0718-01M | 5A | 5 mA | 50Ω | 0. 2 5V | ≤30' | ≤0.25% | ≥2 times of the rated value |
Table 2:
Model | Rated Input Current | Rated Output Current | Rated Sampling Voltage | Phase Shift | Non-linearity | Linear Range |
TA0718-01M | 5A | 5 mA | ≤1/2 times IC’s power supply voltage | ≤5' | ≤0.1% | ≥2 times of the rated value |
8.Attention:
① Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.
② Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.