1.Features:
① Being able to be directly welded on PCB;
②Fully encapsulated, strong mechanical and environmental endurance, strong dielectric strength and beautiful appearance.
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range: 20Hz~1kHz
4.Insulation Thermal Class: Class B (130°C)
5.Safety Features:
① Insulation resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 6KV 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0.
6.Outline Drawing, Installation Dimension and Coil Diagram. ( tolerance ± 0.5mm )
7.Typical Application and Technical Parameters:
①The parameters are listed in Table 1 while the sampling voltage is obtained directly by using a resistor (as shown in Fig.1 below).
②The parameters are listed in Table 2 while the sampling voltage is obtained by using an IC (as shown in Fig.2 below).
Table 1:
Model | Rated Input Current | Rated Output Current | Rated Sampling Resistance | Rated Sampling Voltage | Phase Shift | Non-linearity | Linear Range | Withstand Voltage |
TA500-1 | 200A | 200mA | 75Ω | 15V | ≤30’ | ≤1% | ≥2.5 times of the rated value | ≥6KV |
TA500-2 | 200A | 100mA | 240Ω | 24V | ||||
TA500-3 | 200A | 66.6mA | 495Ω | 33V | ||||
TA500-4 | 200A | 50mA | 900Ω | 45V | ||||
TA500-5 | 200A | 40mA | 1.5KΩ | 60V |
Table 2:
Model | Rated Input Current | Rated Output Current | Rated Sampling Voltage | Phase Shift | Non-linearity | Linear Range | Withstand Voltage |
TA500-1 | 200A | 200mA | ≤1/2 times of IC’s power supply | ≤10’ | ≤0.2% | ≥2.5 times of the rated value | ≥6KV |
TA500-2 | 200A | 100mA | |||||
TA500-3 | 200A | 66.6mA | |||||
TA500-4 | 200A | 50mA | |||||
TA500-5 | 200A | 40mA |
8.Attention:
① Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.
② Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.