TA300 Series Horizontal Core Type Precision AC Current Transformers
7.png
TA300 Series Horizontal Core Type Precision AC Current Transformers
Features:
① Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, safe and reliable;
② Soft line output, easy to use and flexible.
TA300系列 General Technical Specifications for Standard Products:

1Features:

① Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, safe and reliable;

② Soft line output, easy to use and flexible.


 

2Ambient Conditions

① Ambient temperature: -55℃+85℃;

② Relative humidity: ≤90% at 40℃;


③ Atmospheric pressure: 8601060mbar

(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal Class: Class B (130°C)

 5Safety Features:

① Dielectric resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 6KV 50Hz/1min;

③ Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram: ( tolerance ± 0.5mm )

image.pngimage.png

7Typical Application and Technical Parameters: ( tolerance ± 0.5mm )

See the table below for the application performance parameters shown in Figure 3 on the upper right.

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

Rated Sampling Voltage

Phase Shift

Non Linearity

Linear Range

TA300-01M

100A

100mA

50Ω

5V

≤30'

≤0.25%

≥2 times rated value

TA300-02M

100A

50mA

100Ω

10V

≤20'

≤0.25%

Note:

a. In practical applications, the sampling resistor should be less than or equal to the rated value given in the above table, which will improve the nonlinearity and phase shift.

b. If the conversion ratio required by the user is different from the above, it can be customized according to the user's requirements.

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.