Home
Products
Power Transformers
Voltage/Current Transformers
Power Sensors
Power Modules
Anti-resonance Reactors
Applications
Electric Power Automation and Intelligence
Power Equipment
Rail Transit
Industrial Automation
Download
About Us
Contact Us
Login
Register
CN
TA250 Series Vertical Core Type Microminiature Precision AC Current Transformers
TA250系列立式穿芯小型精密交流电流互感器-1.png
TA250 Series Vertical Core Type Microminiature Precision AC Current Transformers
Features:
① Being able to be directly welded on PCB;
② Fully encapsulated, strong mechanical and environmental endurance, strong dielectric strength and beautiful appearance.
TA250系列 General Technical Specifications for Standard Products:

1Features:

 Being able to be directly welded on PCB;

 Fully encapsulated, strong mechanical and environmental endurance, strong dielectric strength and beautiful appearance. 

 

2Ambient Conditions

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal Class: Class B (130°C)

 

5Safety Features:

 Dielectric resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 6KV 50Hz/1min;

 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram: ( tolerance ± 0.5mm )

image.png

 

7Typical Application and Technical Parameters:

 The parameters are listed in Table 1 while the sampling voltage is obtained directly by using a resistor (as shown in Fig.1 below).

 The parameters are listed in Table 2 while the sampling voltage is obtained by using an IC (as shown in Fig.2 below).

image.png

    Table 1

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

Rated  Sampling Voltage

Phase Shift

Non-linearity

Linear Range

Withstand

Voltage

TA250-1

100A

100mA

100Ω

10V

30

1%

2.5 times of

rated value

6KV

TA250-2

100A

50mA

300Ω

15V

TA250-3

100A

33.3mA

690Ω

23V

TA250-4

100A

25mA

1.1KΩ

27.5V

TA250-5

100A

20mA

1.8KΩ

36V

 

    Table 2

Model

Rated Input Current

Rated Output Current

Rated Sampling Voltage

Phase Shift

Non-linearity

Linear Range

Withstand

Voltage

TA250-1

100A

100mA

1/2 times of ICs power supply

10

0.2%

2.5 times of the

rated value

6KV

TA250-2

100A

50mA

TA250-3

100A

33.3mA

TA250-4

100A

25mA

TA250-5

100A

20mA

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.

 


Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search