TA200 Series Vertical Core Type Microminiature Precision AC Current Transformers
TA200系列立式穿芯小型精密-1.gif
TA200 Series Vertical Core Type Microminiature Precision AC Current Transformers
Features:
① Being able to be directly welded on PCB;
② Fully encapsulated, strong mechanical and environmental endurance, strong dielectric strength and beautiful appearance.
TA200 General Technical Specifications for Standard Products:

1Features:

 Being able to be directly welded on PCB;

 Fully encapsulated, strong mechanical and environmental endurance, strong dielectric strength and beautiful appearance. 

 

2Ambient Conditions:

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass B (130°C)

 

5Safety Features:

 Insulation resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 6KV 50Hz/1min;

 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram:( tolerance ± 0.5mm)

image.png

 

7Typical Usage and Technical Parameters:

The parameters are listed in Table 1 while the sampling voltage is obtained directly by using a resistor (as shown in Fig.1 below).

The parameters are listed in Table 2 while the sampling voltage is obtained by using an IC (as shown in Fig.2 below).

image.png


Table 1

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

Rated Sampling Voltage

Phase Shift

Non Linearity

Linear Range

Withstand Voltage

TA200-1

75A

75mA

100Ω

7.5V

30

1%

2.5 times of

the rated value

6KV

TA200-2

75A

37.5mA

400Ω

15V

TA200-3

75A

25mA

800Ω

20V

TA200-3

80A

20mA

1.5KΩ

30V

   

Table 2

Model

Rated Input Current

Rated Output Current

Rated  Sampling Voltage

Phase Shift

Non-linearity

Linear Range

Withstand

Voltage

TA200-1

75A

75mA

1/2 times of ICs power supply

10

0.2%

2.5 times of the

rated value

6KV

TA200-2

75A

37.5mA

TA200-3

75A

25mA

TA200-4

80A

20mA

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.