TA125 Series Vertical Core Type Microminiature Precision AC Current Transformers
TA125系列立式穿芯小型精密交流电流互感器-1.png
TA125 Series Vertical Core Type Microminiature Precision AC Current Transformers
Features:
① Being able to be directly welded on PCB;
② Fully encapsulated, strong mechanical and environmental endurance, strong dielectric strength and beautiful appearance.
TA125系列 General Technical Specifications for Standard Products:

1Features:

 Being able to be directly welded on PCB;

Fully encapsulated, strong mechanical and environmental endurance, strong dielectric strength and beautiful appearance. 

 

2Ambient Conditions:

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass B (130°C)

 

5Safety Features:

 Insulation resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 6KV 50Hz/1min;

 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram:( tolerance ± 0.5mm)

image.png

 

7Typical Application and Technical Parameters:

The parameters are listed in Table 1 while the sampling voltage is obtained directly by using a resistor (as shown in Fig.1 below).

The parameters are listed in Table 2 while the sampling voltage is obtained by using an IC (as shown in Fig.2 below).

image.png

 

Table 1

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

Rated  Sampling Voltage

Phase Shift

Non-linearity

Linear Range

Withstand

Voltage

TA125-1

50A

50mA

100Ω

5V

30

1%

2.5 times of

the rated value

6KV

TA125-2

50A

25mA

400Ω

10V

TA125-3

60A

20mA

750Ω

15V

2 times of

the rated value

Table 2

Model

Rated Input Current

Rated Output Current

Rated  Sampling Voltage

Phase Shift

Non-linearity

Linear Range

Withstand

Voltage

TA125-1

50A

50mA

1/2 times of ICs power supply

10

0.2%

2.5 times of

the rated value

6KV

TA125-2

50A

25mA

TA125-3

60A

20mA

2 times of

the rated value

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.

Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search