TA5A AC Current Transformers with Busbar Built-in
TA5A系列母线内置式交流电-1.gif
TA5A AC Current Transformers with Busbar Built-in
Features:
① The primary coil is built-in inside; being able to be directly soldered on PCB;
② Completely sealed, strong mechanical and environmental endurance, strong dielectric strength, elegant outline
TA5A General Technical Specifications for Standard Products:

1Features:

 The primary coil is built-in inside; being able to be directly soldered on PCB;

 Completely sealed, strong mechanical and environmental endurance, strong dielectric strength, elegant outline

 

2Ambient Conditions:

 Ambient temperature: -55℃+85℃;

 Relative humidity: ≤90% at 40℃;

 Atmospheric pressure: 8601060mbar(about 650800mmHg).

 

3Operating Frequency Range: 20Hz~1kHz

 

4Insulation Thermal ClassClass B (130°C)

 

5Safety Features:

 Dielectric resistance: >1000MΩ in normal condition;

 Insulation withstand voltages: 2KV 50Hz/1min;

 Fire retardancy: In conformity with UL94-V0.

 

6Outline Drawing, Installation Dimension and Coil Diagram:( tolerance ± 0.5mm

image.png


                    image.png

 

7.Typical Application and Technical Parameters:

The sampling voltage is obtained directly by using a resistor.

The parameters are listed in table below.

 

Model

Rated Input Current

Rated Output Current

Rated Sampling Resistance

Rated Sampling Voltage

Phase Shift

Non Linearity

Linear Range

Withstand Voltage

TA5A/0.1A

5A

100mA

30Ω

3V

≤30’

≤0.5%

3 times of the rated value

≥2KV

TA5A/1A

5A

1A

0.3Ω

0.3V

 

Notes:

aIn practical applications, the sampling resistor should be smaller than or equal to rated value given in table above in order to improve non-linearity and phase shift.

bWe can have it customer-made if required current ratio is not listed in the table above.

 

8Attention:

 Connect the primary winding of the current transformer in series with the measured current loop, and operate the secondary winding in near short-circuit mode.

 Do not allow the secondary winding of the current transformer to be open-circuited and do not install any fuse in the secondary circuit.