1.Features:
① This component has a miniature size and high precision. It is capable of being directly soldered onto a PCB, is easy to use, and has an elegant outline.
② This component is fully encapsulated and has strong mechanical and environmental endurance, strong dielectric strength, and is safe and reliable.
2.Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3.Operating Frequency Range : 20Hz~20kHz
4.Insulation Thermal Class: Class F (155℃)
5.Safety Features:
① Dielectric resistance: >1000MΩ in normal condition;
② Insulation withstand voltages: 2KV 50Hz/1min;
③ Fire retardancy: In conformity with UL94-V0.
6.Outline Drawing, Installation Dimension and Coil Diagram(tolerance ± 0.3mm)

7.Typical Application and Technical Parameters
TV1013 is actually a current-type voltage transformer. There are two typical applications shown in Fig.1 and Fig.2, respectively. The parameters are listed in Table 1.

Table 1:
Usage  | Model  | Input Voltage  | Output Voltage  | Phase Shift  | Non Linearity  | Linear Range  | Rated Current  | Withstand Voltage  | 
Used as in Fig.1  | TV1013-1  | ≤1000Vac  | ≤0.5Vac  | ≤30’  | ≤0.2%  | 1.5 times of the rated value  | 2mA/2mA  | ≥2000V  | 
TV1013-1M  | ≤0.625Vac  | ≤40’  | ≤0.25%  | |||||
Used as in Fig.2  | TV1013-1  | ≤1000Vac  | ≤1/2 IC’s power supply  | ≤5’  | ≤0.1%  | 2 times of the rated value  | ||
TV1013-1M  | ≤5’  | ≤0.1%  | 
8.Attention:
This voltage transformer model is a current-type transformer. Therefore, an open circuit is not permitted in the secondary circuit, and no fuse should be connected in the secondary circuit.