Home
Products
Power Transformers
Voltage/Current Transformers
Power Sensors
Power Modules
Anti-resonance Reactors
Applications
Electric Power Automation and Intelligence
Power Equipment
Rail Transit
Industrial Automation
Download
About Us
Contact Us
Login
Register
CN
SC Series Lateral Stand Power Transformers
sc系列全封闭侧立式-1.png
SC Series Lateral Stand Power Transformers
Rated Power: 3VA, 12VA, 60VA
Rated Voltage
① Standard series:
Primary:220V±15%~25% 50Hz/60Hz
Secondary:
single output:6V, 7.5V, 9V, 12V, 15V, 18V, 21V, 24V, 27V
double output:2×6V, 2×7.5V, 2×9V, 2×12V, 2×15V, 2×18V, 2×21V, 2×24V, 2×27V
② Non-standard series: It can be customized based on customer's requirements.
General Technical Specifications for Standard Products:

1.Features① The fully-encapsulated board can be assembled by lateral stand and has a perfect outline, making it easy to use.② It is compact in structure, solid, vibration-proof, moisture-proof, flame-resistant, and has high dielectric strength;③ It has low idle current, high power factor, a wide range of over primary voltage, and a built-in temperature protector, making it safer to use.④ It has welding slips in the output terminals, making it compatible with standard plugs and easy and flexible to use in applications.

 

2.Ambient Conditions:① Ambient temperature: -25℃~+70℃;② Relative humidity: ≤90% at 40℃;③ Atmospheric pressure: 860~1060mbar (650~800mmHg approximately)

3.  Insulation Rating: Class F (155℃)

4.  Safety Features

① Dielectric resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 3750V (50HZ) /1 min;

③ Insulation impact strength: Continuously 20 times impact of 6KV/50μS;

④ Fire retardancy: In conformity with UL94-Vo;

 

5. Safety approval:  

6. Rated Power: 3VA, 12VA, 60VA

 

7. Rated Voltage

① Standard series:

Primary:220V±15%~25%   50Hz/60Hz
Secondary:

single output:6V, 7.5V, 9V, 12V, 15V, 18V, 21V, 24V, 27V

double output:2×6V, 2×7.5V, 2×9V, 2×12V, 2×15V, 2×18V, 2×21V, 2×24V, 2×27V

② Non-standard series: It can be customized based on customer's requirements.

 

8. Universal Technical Parameters of SC Series Standard Product

Power

Model

Idle Current

Idle Loss

Voltage Regulation

Ratio

Temperature

Rise

Weight

(g)

Dimension

(mm)3

L×W×H

3VA

SC3

≤15 mA

≤0.35W

≤15%

≤15℃

165

60.8×34.5×34.8

12VA

SC12

≤25 mA

≤1.0W

≤20%

≤20℃

340

75×38.5×43

60VA

SC60

≤65 mA

≤1.5W

≤9%

≤40℃

1050

94×63×60.5


Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search