1. Features:
① This product has an elegant outline and can be directly soldered onto a PCB.
② Reliable insulation between primary winding and secondary winding, winding and shielding;
③The primary side does not have a series resistance input, and the secondary side directly outputs voltage;
④Fully enclosed, good mechanical and environmental resistance, strong voltage isolation capability, safe and reliable.
2. Ambient Conditions:
① Ambient temperature: -55℃~+85℃;
② Relative humidity: ≤90% at 40℃;
③ Atmospheric pressure: 860~1060mbar(about 650~800mmHg).
3. Operating Frequency Range: 20Hz~1kHz
4. Insulation Thermal Class: Class B (130℃)
5. Safety Features:
① Dielectric resistance:>1000MΩ in normal condition;
② Insulation withstand voltages: 3KV 50Hz/1min in line-frequency;
③ Fire retardancy: In conformity with UL94-V0.
6. Model Naming Rules:

7. Outline Drawing, Installation Dimension:( Figure 2 and Figure 3 ) ( tolerance±0.5mm )

8. Technical Parameters:
Model  | Rated Input Voltage  | Input Voltage  | Rated Output Voltage  | Non-linearity  | Phase Shift  | 
TV1322A-1C  | 150V  | 180V  | 0.5V  | ≤0.5%  | ≤15'  | 
TV1322A-2C  | 100V  | 120V  | 2V  | ≤0.5%  | ≤15'  | 
TV1322B-1C  | 100V  | 120V  | 3.53V  | ≤0.5%  | ≤15'  | 
TV1322B-2C  | 150V  | 180V  | 2V  | ≤0.5%  | ≤15'  | 
Note: Customized products are available if the specification listed above are not met.