“Argent Angel” SL Series Flat PCB Mount Power Transformers
SL30-1.gif
“Argent Angel” SL Series Flat PCB Mount Power Transformers
Rated Power 3VA, 6VA, 9VA, 10VA, 20VA, 30VA, 40VA
Rated Voltage
① Standard series:
Primary:2×110V±15%-20% 50Hz/60Hz
Secondary:2×6V, 2×7.5V, 2×9V, 2×12V, 2×15V, 2×18V, 2×21V, 2×24V, 2×27V
② Non-standard series: It can be customized based on customer's requirements.
General Technical Specifications for Standard Products:

1.  Features

① The fully-encapsulated printed circuit board can be directly welded and assembled, and has a perfect outline.

② It has a low mounting height, compact structure, and is solid, vibration-proof, moisture-proof, flame-resistant, and has high insulation withstand voltages.;

③ It is easy to use and reconfigure, and alternative input/output voltages can be obtained by changing the connections of the primary and/or secondary. 

④ It has a built-in temperature protector, making it safer to use.

2.  Ambient Conditions

① Temperature: -25℃~+70℃;

② Relative humidity: ≤90% at 40℃;

③ Atmospheric pressure: 860~1060mbar (650~800mmHg approximately).

3.  Insulation Rating: Class F (155℃)

4.  Safety Features

① Dielectric resistance: >1000MΩ in normal condition;

② Insulation withstand voltages: 3750 V (50HZ)/1 min;

③ Insulation impact strength: Continuously 20 times impact of 6KV(50HZ)/50μS;

④ Fire retardancy: In conformity with UL94-Vo.

5. Safety approval: 

 

6.  Rated Power   3VA, 6VA, 9VA, 10VA, 20VA, 30VA, 40VA

7.  Rated Voltage

① Standard series:

Primary:2×110V±15%-20%    50Hz/60Hz

Secondary:2×6V, 2×7.5V, 2×9V, 2×12V, 2×15V, 2×18V, 2×21V, 2×24V, 2×27V

② Non-standard series: It can be customized based on customer's requirements.

 

8. Universal Technical Parameters of SL Series Standard Product

No.

Model

Output

Power

Idle Current

Idle Loss

Voltage Regulation Ratio

Temperature

Rise

Weight

(g)

Dimension

L×W×H

(mm)3

1

SL3

3VA

≤12mA

≤0.25W

≤25%

≤20℃

165

53×43×21.5

2

SL6

6VA

≤15mA

≤0.32W

≤24%

≤22℃

220

53×43×25.5

3

SL9

9VA

≤20 mA

≤0.43W

≤23%

≤25℃

280

53×43×30

4

SL10

10VA

≤30 mA

≤0.75W

≤26%

≤30℃

290

68×55×24

5

SL20

20VA

≤50 mA

≤0.85W

≤18%

≤35℃

420

68×55×31

6

SL30

30VA

≤70 mA

≤1.25W

≤13%

≤40℃

540

68×55×37

7

SL40

40VA

≤65 mA

≤1.8W

≤12%

≤45℃

760

83.5×70.5×39



Application Case
Driven by market demand, we are committed to continuous innovation and customer satisfaction.
Standard Product Reservation
Custom Product Reservation
Search